Implementing Cisco Application Centric Infrastructure (DCACI) 300-620 Practice Test 47
Question 460
At fictional Falcon University, the team is reviewing shortcuts for the following ACI issue: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. Which proposal would recreate the same failure?
- Repair a missing AEP domain mapping by changing only the VMware guest IP settings.
- Rename an unrelated VMware port group to imitate the correct APIC EPG name.
- Assume the VMware vMotion task alone provisions the missing ACI leaf access policy.
- Assume deployment immediacy and resolution immediacy refer to the same event.
Explanation
Correct Answer
A:Reject it because it defeats the correction for this observed case: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. The required outcome remains: The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
Incorrect Answers
B:“Rename an unrelated VMware port group to imitate the correct APIC EPG name” represents a different ACI defect involving vMware virtual-port membership does not match the intended ACI EPG classification. The shortcut sought here preserves the access-policy path does not connect the physical VMware uplinks to the VMM domain, so the relevant answer is “Repair a missing AEP domain mapping by changing only the VMware guest IP settings”.
C:“Assume the VMware vMotion task alone provisions the missing ACI leaf access policy” represents a different ACI defect involving vMM endpoint mobility planning omitted the destination host's physical ACI access policies. The shortcut sought here preserves the access-policy path does not connect the physical VMware uplinks to the VMM domain, so the relevant answer is “Repair a missing AEP domain mapping by changing only the VMware guest IP settings”.
D:“Assume deployment immediacy and resolution immediacy refer to the same event” represents a different ACI defect involving the chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved. The shortcut sought here preserves the access-policy path does not connect the physical VMware uplinks to the VMM domain, so the relevant answer is “Repair a missing AEP domain mapping by changing only the VMware guest IP settings”.
Question 461
A Cisco ACI deployment review at fictional Kestrel Cloud identifies this condition: A virtual machine was manually placed in a similarly named port group rather than the APIC-created EPG-backed group. What is the most appropriate next configuration action?
- Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning.
- Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior.
- Create the supported Nutanix VMM domain and connect it to the approved Nutanix management endpoint.
- Choose the supported deployment immediacy option that matches preprovisioning needs and verify effective policy.
Explanation
Correct Answer
A:This change matches the observed ACI failure at Kestrel Cloud. Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning. It corrects the underlying issue that vMware virtual-port membership does not match the intended ACI EPG classification.
Incorrect Answers
B:“Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior” addresses the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design, but the ACI fault here is vMware virtual-port membership does not match the intended ACI EPG classification. The appropriate implementation is “Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning”.
C:“Create the supported Nutanix VMM domain and connect it to the approved Nutanix management endpoint” addresses the ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV, but the ACI fault here is vMware virtual-port membership does not match the intended ACI EPG classification. The appropriate implementation is “Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning”.
D:“Choose the supported deployment immediacy option that matches preprovisioning needs and verify effective policy” addresses the policy deployment timing was not matched to the requirement to preprovision forwarding resources, but the ACI fault here is vMware virtual-port membership does not match the intended ACI EPG classification. The appropriate implementation is “Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning”.
Question 462
At fictional Kestrel Cloud, an ACI deployment failed in this way: A virtual machine was manually placed in a similarly named port group rather than the APIC-created EPG-backed group. Which technical cause best explains it?
- VMware virtual-port membership does not match the intended ACI EPG classification.
- The physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design.
- The ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV.
- The policy deployment timing was not matched to the requirement to preprovision forwarding resources.
Explanation
Correct Answer
A:This is the implicated mechanism, not just a correlated symptom: VMware virtual-port membership does not match the intended ACI EPG classification. The corrective implementation is to attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning.
Incorrect Answers
B:“The physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design” would imply the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The observed fabric issue instead points to vMware virtual-port membership does not match the intended ACI EPG classification.
C:“The ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV” would imply the ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV. The observed fabric issue instead points to vMware virtual-port membership does not match the intended ACI EPG classification.
D:“The policy deployment timing was not matched to the requirement to preprovision forwarding resources” would imply the policy deployment timing was not matched to the requirement to preprovision forwarding resources. The observed fabric issue instead points to vMware virtual-port membership does not match the intended ACI EPG classification.
Question 463
For the ACI issue at fictional Kestrel Cloud: A virtual machine was manually placed in a similarly named port group rather than the APIC-created EPG-backed group. Which finding best demonstrates a successful implementation?
- The VM is classified in the expected tenant EPG and its contract policies apply.
- The VM keeps the expected EPG connectivity after the selected uplink is disconnected.
- The intended Nutanix cluster appears under its proper APIC VMM domain with functional policy mapping.
- The required leaf policy is present at the intended time before the application cutover.
Explanation
Correct Answer
A:The needed validation is specific to this defect: VMware virtual-port membership does not match the intended ACI EPG classification. The observation that confirms the repair is: The VM is classified in the expected tenant EPG and its contract policies apply.
Incorrect Answers
B:The observation is appropriate when the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The requested sign-off must instead show: The VM is classified in the expected tenant EPG and its contract policies apply.
C:The observation is appropriate when the ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV. The requested sign-off must instead show: The VM is classified in the expected tenant EPG and its contract policies apply.
D:The observation is appropriate when the policy deployment timing was not matched to the requirement to preprovision forwarding resources. The requested sign-off must instead show: The VM is classified in the expected tenant EPG and its contract policies apply.
Question 464
Following remediation at fictional Kestrel Cloud, what recurring validation should guard against this failure returning? The original issue was: A virtual machine was manually placed in a similarly named port group rather than the APIC-created EPG-backed group.
- Repeat a documented regression test confirming: the VM keeps the expected EPG connectivity after the selected uplink is disconnected.
- Repeat a documented regression test confirming: the intended Nutanix cluster appears under its proper APIC VMM domain with functional policy mapping.
- Repeat a documented regression test confirming: the VM is classified in the expected tenant EPG and its contract policies apply.
- Repeat a documented regression test confirming: the required leaf policy is present at the intended time before the application cutover.
Explanation
Correct Answer
C:A scheduled check should confirm that the VM is classified in the expected tenant EPG and its contract policies apply. This helps show the corrected policy relationship remains healthy after future changes.
Incorrect Answers
A:“Repeat a documented regression test confirming: the VM keeps the expected EPG connectivity after the selected uplink is disconnected” is a regression check for the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. It does not retest the actual failure, vMware virtual-port membership does not match the intended ACI EPG classification; use the case-specific result “Repeat a documented regression test confirming: the VM is classified in the expected tenant EPG and its contract policies apply”.
B:“Repeat a documented regression test confirming: the intended Nutanix cluster appears under its proper APIC VMM domain with functional policy mapping” is a regression check for the ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV. It does not retest the actual failure, vMware virtual-port membership does not match the intended ACI EPG classification; use the case-specific result “Repeat a documented regression test confirming: the VM is classified in the expected tenant EPG and its contract policies apply”.
D:“Repeat a documented regression test confirming: the required leaf policy is present at the intended time before the application cutover” is a regression check for the policy deployment timing was not matched to the requirement to preprovision forwarding resources. It does not retest the actual failure, vMware virtual-port membership does not match the intended ACI EPG classification; use the case-specific result “Repeat a documented regression test confirming: the VM is classified in the expected tenant EPG and its contract policies apply”.
Question 465
A change reviewer at fictional Kestrel Cloud sees: A virtual machine was manually placed in a similarly named port group rather than the APIC-created EPG-backed group. Which tempting simplification should be rejected?
- Call an unsupported collection of independent switch ports a resilient VMware vPC uplink.
- Rename an unrelated VMware port group to imitate the correct APIC EPG name.
- Treat Nutanix AHV and VMware vCenter as interchangeable VMM provider types.
- Treat on-demand deployment as proof that every unused leaf is already programmed.
Explanation
Correct Answer
B:The proposed shortcut would preserve the wrong assumption at Kestrel Cloud. The team should instead implement: Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning.
Incorrect Answers
A:“Call an unsupported collection of independent switch ports a resilient VMware vPC uplink” represents a different ACI defect involving the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The shortcut sought here preserves vMware virtual-port membership does not match the intended ACI EPG classification, so the relevant answer is “Rename an unrelated VMware port group to imitate the correct APIC EPG name”.
C:“Treat Nutanix AHV and VMware vCenter as interchangeable VMM provider types” represents a different ACI defect involving the ACI integration uses the wrong VMM provider and inventory workflow for Nutanix AHV. The shortcut sought here preserves vMware virtual-port membership does not match the intended ACI EPG classification, so the relevant answer is “Rename an unrelated VMware port group to imitate the correct APIC EPG name”.
D:“Treat on-demand deployment as proof that every unused leaf is already programmed” represents a different ACI defect involving the policy deployment timing was not matched to the requirement to preprovision forwarding resources. The shortcut sought here preserves vMware virtual-port membership does not match the intended ACI EPG classification, so the relevant answer is “Rename an unrelated VMware port group to imitate the correct APIC EPG name”.
Question 466
Engineers at fictional Summit Retail report: Virtual machines lose network access after an ESXi uplink failure even though the DVS shows a surviving uplink. Which implementation step should be prioritized?
- Validate the new vCenter certificate and repair the supported APIC VMM trust configuration.
- Select supported static VLAN mode with an eligible port encapsulation and verify the Nutanix subnet mapping.
- Document and test resolution and deployment immediacy independently using a new VM attachment.
- Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior.
Explanation
Correct Answer
D:This change matches the observed ACI failure at Summit Retail. Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior. It corrects the underlying issue that the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design.
Incorrect Answers
A:“Validate the new vCenter certificate and repair the supported APIC VMM trust configuration” addresses the management trust relationship to vCenter was not updated after the certificate change, but the ACI fault here is the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The appropriate implementation is “Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior”.
B:“Select supported static VLAN mode with an eligible port encapsulation and verify the Nutanix subnet mapping” addresses the Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation, but the ACI fault here is the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The appropriate implementation is “Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior”.
C:“Document and test resolution and deployment immediacy independently using a new VM attachment” addresses the runbook fails to distinguish the two separate VMM immediacy controls, but the ACI fault here is the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The appropriate implementation is “Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior”.
Question 467
After checking the symptoms at fictional Summit Retail: Virtual machines lose network access after an ESXi uplink failure even though the DVS shows a surviving uplink. Which policy or topology defect is most likely?
- The physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design.
- The management trust relationship to vCenter was not updated after the certificate change.
- The Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation.
- The runbook fails to distinguish the two separate VMM immediacy controls.
Explanation
Correct Answer
A:This is the implicated mechanism, not just a correlated symptom: The physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The corrective implementation is to align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior.
Incorrect Answers
B:“The management trust relationship to vCenter was not updated after the certificate change” would imply the management trust relationship to vCenter was not updated after the certificate change. The observed fabric issue instead points to the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design.
C:“The Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation” would imply the Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation. The observed fabric issue instead points to the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design.
D:“The runbook fails to distinguish the two separate VMM immediacy controls” would imply the runbook fails to distinguish the two separate VMM immediacy controls. The observed fabric issue instead points to the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design.
Question 468
After the ACI configuration is corrected at fictional Summit Retail, the engineer needs proof that this issue is resolved: Virtual machines lose network access after an ESXi uplink failure even though the DVS shows a surviving uplink. Which observation is the strongest evidence?
- VMM inventory synchronization succeeds with valid certificate validation.
- The Nutanix subnet uses the approved VLAN and the corresponding ACI EPG has consistent encapsulation.
- The VM keeps the expected EPG connectivity after the selected uplink is disconnected.
- The observed VMM port-group resolution and leaf policy programming each occur at their configured stages.
Explanation
Correct Answer
C:The needed validation is specific to this defect: The physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The observation that confirms the repair is: The VM keeps the expected EPG connectivity after the selected uplink is disconnected.
Incorrect Answers
A:The observation is appropriate when the management trust relationship to vCenter was not updated after the certificate change. The requested sign-off must instead show: The VM keeps the expected EPG connectivity after the selected uplink is disconnected.
B:The observation is appropriate when the Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation. The requested sign-off must instead show: The VM keeps the expected EPG connectivity after the selected uplink is disconnected.
D:“The observed VMM port-group resolution and leaf policy programming each occur at their configured stages” could verify the runbook fails to distinguish the two separate VMM immediacy controls, not the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. Confirm instead that the VM keeps the expected EPG connectivity after the selected uplink is disconnected.
Question 469
A maintenance standard is being revised after this ACI fault at fictional Summit Retail: Virtual machines lose network access after an ESXi uplink failure even though the DVS shows a surviving uplink. Which ongoing verification is most relevant?
- Repeat a documented regression test confirming: vMM inventory synchronization succeeds with valid certificate validation.
- Repeat a documented regression test confirming: the VM keeps the expected EPG connectivity after the selected uplink is disconnected.
- Repeat a documented regression test confirming: the Nutanix subnet uses the approved VLAN and the corresponding ACI EPG has consistent encapsulation.
- Repeat a documented regression test confirming: the observed VMM port-group resolution and leaf policy programming each occur at their configured stages.
Explanation
Correct Answer
B:A scheduled check should confirm that the VM keeps the expected EPG connectivity after the selected uplink is disconnected. This helps show the corrected policy relationship remains healthy after future changes.
Incorrect Answers
A:“Repeat a documented regression test confirming: vMM inventory synchronization succeeds with valid certificate validation” is a regression check for the management trust relationship to vCenter was not updated after the certificate change. It does not retest the actual failure, the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design; use the case-specific result “Repeat a documented regression test confirming: the VM keeps the expected EPG connectivity after the selected uplink is disconnected”.
C:“Repeat a documented regression test confirming: the Nutanix subnet uses the approved VLAN and the corresponding ACI EPG has consistent encapsulation” is a regression check for the Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation. It does not retest the actual failure, the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design; use the case-specific result “Repeat a documented regression test confirming: the VM keeps the expected EPG connectivity after the selected uplink is disconnected”.
D:“Repeat a documented regression test confirming: the observed VMM port-group resolution and leaf policy programming each occur at their configured stages” is a regression check for the runbook fails to distinguish the two separate VMM immediacy controls. It does not retest the actual failure, the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design; use the case-specific result “Repeat a documented regression test confirming: the VM keeps the expected EPG connectivity after the selected uplink is disconnected”.
Question 470
During a post-incident review at fictional Summit Retail, the original condition was: Virtual machines lose network access after an ESXi uplink failure even though the DVS shows a surviving uplink. Which shortcut would leave its cause in place?
- Disable certificate checking globally so every subsequent vCenter change is silently trusted.
- Call an unsupported collection of independent switch ports a resilient VMware vPC uplink.
- Assume a dynamic VLAN assignment always equals a required preassigned Nutanix VLAN.
- Change both immediacy knobs blindly whenever only leaf programming timing is in question.
Explanation
Correct Answer
B:The proposed shortcut would preserve the wrong assumption at Summit Retail. The team should instead implement: Align the DVS uplink teaming and ACI leaf port-channel or vPC policies and test failure behavior.
Incorrect Answers
A:“Disable certificate checking globally so every subsequent vCenter change is silently trusted” represents a different ACI defect involving the management trust relationship to vCenter was not updated after the certificate change. The shortcut sought here preserves the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design, so the relevant answer is “Call an unsupported collection of independent switch ports a resilient VMware vPC uplink”.
C:“Assume a dynamic VLAN assignment always equals a required preassigned Nutanix VLAN” represents a different ACI defect involving the Nutanix VMM EPG VLAN mode does not implement the required fixed encapsulation. The shortcut sought here preserves the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design, so the relevant answer is “Call an unsupported collection of independent switch ports a resilient VMware vPC uplink”.
D:“Change both immediacy knobs blindly whenever only leaf programming timing is in question” represents a different ACI defect involving the runbook fails to distinguish the two separate VMM immediacy controls. The shortcut sought here preserves the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design, so the relevant answer is “Call an unsupported collection of independent switch ports a resilient VMware vPC uplink”.