Implementing Cisco Application Centric Infrastructure (DCACI) 300-620 Practice Test 46
Question 450
During a post-incident review at fictional Nova Aero, the original condition was: A production vCenter contains multiple DVS instances, but the APIC VMM domain is associated with a testing DVS. Which shortcut would leave its cause in place?
- Bind the VM port group to any arbitrary VLAN outside the domain pool.
- Call an unsupported collection of independent switch ports a resilient VMware vPC uplink.
- Force a live occupied Nutanix subnet's VLAN to change in place without migration planning.
- Assume any vCenter DVS can carry a production EPG without matching domain association.
Explanation
Correct Answer
D:Reject it because it defeats the correction for this observed case: A production vCenter contains multiple DVS instances, but the APIC VMM domain is associated with a testing DVS. The required outcome remains: The EPG-backed port groups appear on the DVS used by the production VMs.
Incorrect Answers
A:“Bind the VM port group to any arbitrary VLAN outside the domain pool” represents a different ACI defect involving the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. The shortcut sought here preserves the VMM domain targets a virtual switch other than the one used by the application VMs, so the relevant answer is “Assume any vCenter DVS can carry a production EPG without matching domain association”.
B:“Call an unsupported collection of independent switch ports a resilient VMware vPC uplink” represents a different ACI defect involving the physical vPC or uplink policy and VMware teaming do not match the supported ACI attachment design. The shortcut sought here preserves the VMM domain targets a virtual switch other than the one used by the application VMs, so the relevant answer is “Assume any vCenter DVS can carry a production EPG without matching domain association”.
C:“Force a live occupied Nutanix subnet's VLAN to change in place without migration planning” represents a different ACI defect involving the change process ignores Nutanix restrictions on changing a VLAN ID for an occupied subnet. The shortcut sought here preserves the VMM domain targets a virtual switch other than the one used by the application VMs, so the relevant answer is “Assume any vCenter DVS can carry a production EPG without matching domain association”.
Question 451
During a data center change at fictional Cedar Health, the following issue occurs: VMware port groups are created but ACI cannot allocate a VLAN for the new EPG from the VMM domain. What targeted correction should the engineer select?
- Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups.
- Validate the new vCenter certificate and repair the supported APIC VMM trust configuration.
- Verify the installed APIC release and choose only supported Nutanix resolution-immediacy settings.
- Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG.
Explanation
Correct Answer
D:The direct correction is to associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG. This addresses the specific defect: The VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. Validate the outcome by confirming: APIC allocates an eligible VLAN and the port group uses the expected encapsulation.
Incorrect Answers
A:“Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups” addresses the access-policy path does not connect the physical VMware uplinks to the VMM domain, but the ACI fault here is the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. The appropriate implementation is “Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG”.
B:“Validate the new vCenter certificate and repair the supported APIC VMM trust configuration” addresses the management trust relationship to vCenter was not updated after the certificate change, but the ACI fault here is the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. The appropriate implementation is “Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG”.
C:“Verify the installed APIC release and choose only supported Nutanix resolution-immediacy settings” addresses the integration policy ignores software-release-dependent Nutanix resolution-immediacy support, but the ACI fault here is the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. The appropriate implementation is “Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG”.
Question 452
During a Cisco ACI troubleshooting review at fictional Cedar Health, the team finds: VMware port groups are created but ACI cannot allocate a VLAN for the new EPG from the VMM domain. Which design or configuration mistake best accounts for the observation?
- The access-policy path does not connect the physical VMware uplinks to the VMM domain.
- The management trust relationship to vCenter was not updated after the certificate change.
- The integration policy ignores software-release-dependent Nutanix resolution-immediacy support.
- The VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool.
Explanation
Correct Answer
D:The configuration explains the observed behavior because the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. The remedy is: Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG.
Incorrect Answers
A:“The access-policy path does not connect the physical VMware uplinks to the VMM domain” would imply the access-policy path does not connect the physical VMware uplinks to the VMM domain. The observed fabric issue instead points to the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool.
B:“The management trust relationship to vCenter was not updated after the certificate change” would imply the management trust relationship to vCenter was not updated after the certificate change. The observed fabric issue instead points to the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool.
C:“The integration policy ignores software-release-dependent Nutanix resolution-immediacy support” would imply the integration policy ignores software-release-dependent Nutanix resolution-immediacy support. The observed fabric issue instead points to the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool.
Question 453
A change-validation meeting at fictional Cedar Health reviews this issue: VMware port groups are created but ACI cannot allocate a VLAN for the new EPG from the VMM domain. Which test outcome should be required for sign-off?
- The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
- APIC allocates an eligible VLAN and the port group uses the expected encapsulation.
- VMM inventory synchronization succeeds with valid certificate validation.
- The selected policy is valid for the deployed APIC version and the Nutanix integration resolves correctly.
Explanation
Correct Answer
B:This verifies the intended ACI change: Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG. It addresses the original behavior rather than only showing unrelated system health.
Incorrect Answers
A:“The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD” could verify the access-policy path does not connect the physical VMware uplinks to the VMM domain, not the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. Confirm instead that APIC allocates an eligible VLAN and the port group uses the expected encapsulation.
C:“VMM inventory synchronization succeeds with valid certificate validation” could verify the management trust relationship to vCenter was not updated after the certificate change, not the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. Confirm instead that APIC allocates an eligible VLAN and the port group uses the expected encapsulation.
D:“The selected policy is valid for the deployed APIC version and the Nutanix integration resolves correctly” could verify the integration policy ignores software-release-dependent Nutanix resolution-immediacy support, not the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. Confirm instead that APIC allocates an eligible VLAN and the port group uses the expected encapsulation.
Question 454
The operations team at fictional Cedar Health wants to detect recurrence of: VMware port groups are created but ACI cannot allocate a VLAN for the new EPG from the VMM domain. Which repeatable control should be adopted?
- Repeat a documented regression test confirming: aPIC allocates an eligible VLAN and the port group uses the expected encapsulation.
- Repeat a documented regression test confirming: the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
- Repeat a documented regression test confirming: vMM inventory synchronization succeeds with valid certificate validation.
- Repeat a documented regression test confirming: the selected policy is valid for the deployed APIC version and the Nutanix integration resolves correctly.
Explanation
Correct Answer
A:The selected control exercises the intended VMM VLAN pool association design. Without checking this result, the team may overlook a recurrence of the original issue.
Incorrect Answers
B:“Repeat a documented regression test confirming: the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD” is a regression check for the access-policy path does not connect the physical VMware uplinks to the VMM domain. It does not retest the actual failure, the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool; use the case-specific result “Repeat a documented regression test confirming: aPIC allocates an eligible VLAN and the port group uses the expected encapsulation”.
C:“Repeat a documented regression test confirming: vMM inventory synchronization succeeds with valid certificate validation” is a regression check for the management trust relationship to vCenter was not updated after the certificate change. It does not retest the actual failure, the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool; use the case-specific result “Repeat a documented regression test confirming: aPIC allocates an eligible VLAN and the port group uses the expected encapsulation”.
D:“Repeat a documented regression test confirming: the selected policy is valid for the deployed APIC version and the Nutanix integration resolves correctly” is a regression check for the integration policy ignores software-release-dependent Nutanix resolution-immediacy support. It does not retest the actual failure, the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool; use the case-specific result “Repeat a documented regression test confirming: aPIC allocates an eligible VLAN and the port group uses the expected encapsulation”.
Question 455
Engineers at fictional Cedar Health want to avoid repeating: VMware port groups are created but ACI cannot allocate a VLAN for the new EPG from the VMM domain. Which proposed action is unsafe for this specific reason?
- Repair a missing AEP domain mapping by changing only the VMware guest IP settings.
- Disable certificate checking globally so every subsequent vCenter change is silently trusted.
- Copy VMware resolution-immediacy defaults into every Nutanix environment without version checks.
- Bind the VM port group to any arbitrary VLAN outside the domain pool.
Explanation
Correct Answer
D:This proposal reintroduces the underlying failure: The VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool. The supported alternative is: Associate or extend the approved dynamic VLAN pool and verify free encapsulation for the EPG.
Incorrect Answers
A:“Repair a missing AEP domain mapping by changing only the VMware guest IP settings” represents a different ACI defect involving the access-policy path does not connect the physical VMware uplinks to the VMM domain. The shortcut sought here preserves the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool, so the relevant answer is “Bind the VM port group to any arbitrary VLAN outside the domain pool”.
B:“Disable certificate checking globally so every subsequent vCenter change is silently trusted” represents a different ACI defect involving the management trust relationship to vCenter was not updated after the certificate change. The shortcut sought here preserves the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool, so the relevant answer is “Bind the VM port group to any arbitrary VLAN outside the domain pool”.
C:“Copy VMware resolution-immediacy defaults into every Nutanix environment without version checks” represents a different ACI defect involving the integration policy ignores software-release-dependent Nutanix resolution-immediacy support. The shortcut sought here preserves the VMM domain does not have an eligible encapsulation VLAN in its associated dynamic pool, so the relevant answer is “Bind the VM port group to any arbitrary VLAN outside the domain pool”.
Question 456
At fictional Falcon University (research computing), the ACI operations team observes: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. Which change most directly addresses the issue?
- Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning.
- Correct the target ESXi uplink AEP and VMM domain associations and verify migration forwarding.
- Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups.
- Select and validate the supported resolution-immediacy behavior for the VMM workload lifecycle.
Explanation
Correct Answer
C:Choosing this targeted change is preferable to modifying unrelated policies. Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups. The evidence of success should be: The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
Incorrect Answers
A:“Attach the VM NIC to the correctly mapped VMM EPG port group and verify endpoint learning” addresses vMware virtual-port membership does not match the intended ACI EPG classification, but the ACI fault here is the access-policy path does not connect the physical VMware uplinks to the VMM domain. The appropriate implementation is “Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups”.
B:“Correct the target ESXi uplink AEP and VMM domain associations and verify migration forwarding” addresses vMM endpoint mobility planning omitted the destination host's physical ACI access policies, but the ACI fault here is the access-policy path does not connect the physical VMware uplinks to the VMM domain. The appropriate implementation is “Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups”.
D:“Select and validate the supported resolution-immediacy behavior for the VMM workload lifecycle” addresses the chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved, but the ACI fault here is the access-policy path does not connect the physical VMware uplinks to the VMM domain. The appropriate implementation is “Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups”.
Question 457
The network incident record for fictional Falcon University states: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. What underlying fault should the engineer investigate first?
- The access-policy path does not connect the physical VMware uplinks to the VMM domain.
- VMware virtual-port membership does not match the intended ACI EPG classification.
- VMM endpoint mobility planning omitted the destination host's physical ACI access policies.
- The chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved.
Explanation
Correct Answer
A:The described topology and policy would produce the symptom because the access-policy path does not connect the physical VMware uplinks to the VMM domain. The planned fix should be: Associate the VMM domain with the correct AEP used by the leaf uplink interface policy groups.
Incorrect Answers
B:“VMware virtual-port membership does not match the intended ACI EPG classification” would imply vMware virtual-port membership does not match the intended ACI EPG classification. The observed fabric issue instead points to the access-policy path does not connect the physical VMware uplinks to the VMM domain.
C:“VMM endpoint mobility planning omitted the destination host's physical ACI access policies” would imply vMM endpoint mobility planning omitted the destination host's physical ACI access policies. The observed fabric issue instead points to the access-policy path does not connect the physical VMware uplinks to the VMM domain.
D:“The chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved” would imply the chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved. The observed fabric issue instead points to the access-policy path does not connect the physical VMware uplinks to the VMM domain.
Question 458
The network lead at fictional Falcon University is validating remediation of: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. Which result confirms the specific fix?
- The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
- The VM is classified in the expected tenant EPG and its contract policies apply.
- The migrated VM retains its intended EPG policy on the destination host.
- The EPG and virtual-network resolution occurs at the documented VM lifecycle stage.
Explanation
Correct Answer
A:The outcome directly tests the corrected VMM domain AEP association behavior. The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD. It provides stronger evidence than a generic green dashboard or link-up check.
Incorrect Answers
B:“The VM is classified in the expected tenant EPG and its contract policies apply” could verify vMware virtual-port membership does not match the intended ACI EPG classification, not the access-policy path does not connect the physical VMware uplinks to the VMM domain. Confirm instead that the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
C:“The migrated VM retains its intended EPG policy on the destination host” could verify vMM endpoint mobility planning omitted the destination host's physical ACI access policies, not the access-policy path does not connect the physical VMware uplinks to the VMM domain. Confirm instead that the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
D:“The EPG and virtual-network resolution occurs at the documented VM lifecycle stage” could verify the chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved, not the access-policy path does not connect the physical VMware uplinks to the VMM domain. Confirm instead that the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
Question 459
After correcting this issue at fictional Falcon University: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. Which scheduled check best protects the corrected design?
- Repeat a documented regression test confirming: the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
- Repeat a documented regression test confirming: the VM is classified in the expected tenant EPG and its contract policies apply.
- Repeat a documented regression test confirming: the migrated VM retains its intended EPG policy on the destination host.
- Repeat a documented regression test confirming: the EPG and virtual-network resolution occurs at the documented VM lifecycle stage.
Explanation
Correct Answer
A:The safeguard focuses on the actual root defect: The access-policy path does not connect the physical VMware uplinks to the VMM domain. Retesting this outcome can catch a later policy or topology drift.
Incorrect Answers
B:“Repeat a documented regression test confirming: the VM is classified in the expected tenant EPG and its contract policies apply” is a regression check for vMware virtual-port membership does not match the intended ACI EPG classification. It does not retest the actual failure, the access-policy path does not connect the physical VMware uplinks to the VMM domain; use the case-specific result “Repeat a documented regression test confirming: the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD”.
C:“Repeat a documented regression test confirming: the migrated VM retains its intended EPG policy on the destination host” is a regression check for vMM endpoint mobility planning omitted the destination host's physical ACI access policies. It does not retest the actual failure, the access-policy path does not connect the physical VMware uplinks to the VMM domain; use the case-specific result “Repeat a documented regression test confirming: the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD”.
D:“Repeat a documented regression test confirming: the EPG and virtual-network resolution occurs at the documented VM lifecycle stage” is a regression check for the chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved. It does not retest the actual failure, the access-policy path does not connect the physical VMware uplinks to the VMM domain; use the case-specific result “Repeat a documented regression test confirming: the server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD”.
Question 460
At fictional Falcon University, the team is reviewing shortcuts for the following ACI issue: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. Which proposal would recreate the same failure?
- Repair a missing AEP domain mapping by changing only the VMware guest IP settings.
- Rename an unrelated VMware port group to imitate the correct APIC EPG name.
- Assume the VMware vMotion task alone provisions the missing ACI leaf access policy.
- Assume deployment immediacy and resolution immediacy refer to the same event.
Explanation
Correct Answer
A:Reject it because it defeats the correction for this observed case: VMware VMs appear in a VMM EPG but their uplink leaf ports lack the domain's AEP association. The required outcome remains: The server uplinks accept the VMM EPG encapsulation and traffic reaches the intended BD.
Incorrect Answers
B:“Rename an unrelated VMware port group to imitate the correct APIC EPG name” represents a different ACI defect involving vMware virtual-port membership does not match the intended ACI EPG classification. The shortcut sought here preserves the access-policy path does not connect the physical VMware uplinks to the VMM domain, so the relevant answer is “Repair a missing AEP domain mapping by changing only the VMware guest IP settings”.
C:“Assume the VMware vMotion task alone provisions the missing ACI leaf access policy” represents a different ACI defect involving vMM endpoint mobility planning omitted the destination host's physical ACI access policies. The shortcut sought here preserves the access-policy path does not connect the physical VMware uplinks to the VMM domain, so the relevant answer is “Repair a missing AEP domain mapping by changing only the VMware guest IP settings”.
D:“Assume deployment immediacy and resolution immediacy refer to the same event” represents a different ACI defect involving the chosen resolution-immediacy behavior does not match the planned point at which the policy is resolved. The shortcut sought here preserves the access-policy path does not connect the physical VMware uplinks to the VMM domain, so the relevant answer is “Repair a missing AEP domain mapping by changing only the VMware guest IP settings”.