Pass Cisco DCACI 300-620 Exam in First Attempt Easily

Latest Cisco DCACI 300-620 Practice Test Questions, DCACI Exam Dumps
Accurate & Verified Answers As Experienced in the Actual Test!

You save
$39.99
Save
Verified by experts
300-620 Premium Bundle
Exam Code: 300-620
Exam Name: Implementing Cisco Application Centric Infrastructure (DCACI)
Certification Provider: Cisco
Bundle includes 3 products: Premium File, Training Course, Study Guide
accept downloads in the last 7 days
300-620 Premium Bundle
  • Premium File 450 Questions & Answers
    Last Update: Nov 15, 2026
  • Training Course 38 Lectures
  • Study Guide 1221 Pages

Implementing Cisco Application Centric Infrastructure (DCACI) 300-620 Practice Test 68

Question 670

Engineers at fictional Orion Media want to avoid repeating: A privileged APIC role is assigned temporarily but no audit trail records who approved or removed it. Which proposed action is unsafe for this specific reason?

  1. Expose the AAA server to the public internet solely to avoid internal routing.
  2. Upgrade all fabric spines simultaneously because APIC controllers remain powered on.
  3. Assume successful SNMP polling automatically configures trap delivery.
  4. Use a shared administrator credential so individual role changes need no review.

Explanation

Correct Answer

D:

This proposal reintroduces the underlying failure: Privilege-management workflow does not integrate role changes with APIC audit records and approvals. The supported alternative is: Use time-bounded privileged access with recorded approval and audit review.

Incorrect Answers

A:

“Expose the AAA server to the public internet solely to avoid internal routing” represents a different ACI defect involving the AAA integration does not meet the deployment's approved management transport and server trust requirements. The shortcut sought here preserves privilege-management workflow does not integrate role changes with APIC audit records and approvals, so the relevant answer is “Use a shared administrator credential so individual role changes need no review”.

B:

“Upgrade all fabric spines simultaneously because APIC controllers remain powered on” represents a different ACI defect involving the upgrade grouping ignores fabric availability and redundancy requirements. The shortcut sought here preserves privilege-management workflow does not integrate role changes with APIC audit records and approvals, so the relevant answer is “Use a shared administrator credential so individual role changes need no review”.

C:

“Assume successful SNMP polling automatically configures trap delivery” represents a different ACI defect involving the notification destination or trap policy is not configured for the intended receiver. The shortcut sought here preserves privilege-management workflow does not integrate role changes with APIC audit records and approvals, so the relevant answer is “Use a shared administrator credential so individual role changes need no review”.

Question 671

At fictional Trellis Education (education technology), the ACI operations team observes: An administrator configures authentication against a remote server over an unapproved unsecured management path. Which change most directly addresses the issue?

  1. Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence.
  2. Configure a supported authenticated AAA path over the approved management network and verify server trust.
  3. Import and assign the supported firmware image matching the target platform and release.
  4. Store approved backups in access-restricted protected storage and audit retrieval rights.

Explanation

Correct Answer

B:

The direct correction is to configure a supported authenticated AAA path over the approved management network and verify server trust. This addresses the specific defect: The AAA integration does not meet the deployment's approved management transport and server trust requirements. Validate the outcome by confirming: Login requests reach only the authorized AAA server through the permitted management path.

Incorrect Answers

A:

“Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence” addresses the maintenance plan does not follow supported controller/switch version compatibility and ordering, but the ACI fault here is the AAA integration does not meet the deployment's approved management transport and server trust requirements. The appropriate implementation is “Configure a supported authenticated AAA path over the approved management network and verify server trust”.

C:

“Import and assign the supported firmware image matching the target platform and release” addresses the selected firmware image is not compatible with the targeted ACI nodes, but the ACI fault here is the AAA integration does not meet the deployment's approved management transport and server trust requirements. The appropriate implementation is “Configure a supported authenticated AAA path over the approved management network and verify server trust”.

D:

“Store approved backups in access-restricted protected storage and audit retrieval rights” addresses backup custody lacks the access control and protection required for sensitive configuration material, but the ACI fault here is the AAA integration does not meet the deployment's approved management transport and server trust requirements. The appropriate implementation is “Configure a supported authenticated AAA path over the approved management network and verify server trust”.

Question 672

The network incident record for fictional Trellis Education states: An administrator configures authentication against a remote server over an unapproved unsecured management path. What underlying fault should the engineer investigate first?

  1. The maintenance plan does not follow supported controller/switch version compatibility and ordering.
  2. The AAA integration does not meet the deployment's approved management transport and server trust requirements.
  3. The selected firmware image is not compatible with the targeted ACI nodes.
  4. Backup custody lacks the access control and protection required for sensitive configuration material.

Explanation

Correct Answer

B:

The configuration explains the observed behavior because the AAA integration does not meet the deployment's approved management transport and server trust requirements. The remedy is: Configure a supported authenticated AAA path over the approved management network and verify server trust.

Incorrect Answers

A:

“The maintenance plan does not follow supported controller/switch version compatibility and ordering” would imply the maintenance plan does not follow supported controller/switch version compatibility and ordering. The observed fabric issue instead points to the AAA integration does not meet the deployment's approved management transport and server trust requirements.

C:

“The selected firmware image is not compatible with the targeted ACI nodes” would imply the selected firmware image is not compatible with the targeted ACI nodes. The observed fabric issue instead points to the AAA integration does not meet the deployment's approved management transport and server trust requirements.

D:

“Backup custody lacks the access control and protection required for sensitive configuration material” would imply backup custody lacks the access control and protection required for sensitive configuration material. The observed fabric issue instead points to the AAA integration does not meet the deployment's approved management transport and server trust requirements.

Question 673

The network lead at fictional Trellis Education is validating remediation of: An administrator configures authentication against a remote server over an unapproved unsecured management path. Which result confirms the specific fix?

  1. The controller and selected leaf versions satisfy the published compatibility requirements after upgrade.
  2. Login requests reach only the authorized AAA server through the permitted management path.
  3. The correct image is validated and accepted for the intended node upgrade group.
  4. Only authorized recovery personnel can retrieve configuration exports and access is logged.

Explanation

Correct Answer

B:

This verifies the intended ACI change: Configure a supported authenticated AAA path over the approved management network and verify server trust. It addresses the original behavior rather than only showing unrelated system health.

Incorrect Answers

A:

“The controller and selected leaf versions satisfy the published compatibility requirements after upgrade” could verify the maintenance plan does not follow supported controller/switch version compatibility and ordering, not the AAA integration does not meet the deployment's approved management transport and server trust requirements. Confirm instead that login requests reach only the authorized AAA server through the permitted management path.

C:

“The correct image is validated and accepted for the intended node upgrade group” could verify the selected firmware image is not compatible with the targeted ACI nodes, not the AAA integration does not meet the deployment's approved management transport and server trust requirements. Confirm instead that login requests reach only the authorized AAA server through the permitted management path.

D:

“Only authorized recovery personnel can retrieve configuration exports and access is logged” could verify backup custody lacks the access control and protection required for sensitive configuration material, not the AAA integration does not meet the deployment's approved management transport and server trust requirements. Confirm instead that login requests reach only the authorized AAA server through the permitted management path.

Question 674

After correcting this issue at fictional Trellis Education: An administrator configures authentication against a remote server over an unapproved unsecured management path. Which scheduled check best protects the corrected design?

  1. Repeat a documented regression test confirming: the controller and selected leaf versions satisfy the published compatibility requirements after upgrade.
  2. Repeat a documented regression test confirming: the correct image is validated and accepted for the intended node upgrade group.
  3. Repeat a documented regression test confirming: only authorized recovery personnel can retrieve configuration exports and access is logged.
  4. Repeat a documented regression test confirming: login requests reach only the authorized AAA server through the permitted management path.

Explanation

Correct Answer

D:

The selected control exercises the intended External AAA secure transport design. Without checking this result, the team may overlook a recurrence of the original issue.

Incorrect Answers

A:

“Repeat a documented regression test confirming: the controller and selected leaf versions satisfy the published compatibility requirements after upgrade” is a regression check for the maintenance plan does not follow supported controller/switch version compatibility and ordering. It does not retest the actual failure, the AAA integration does not meet the deployment's approved management transport and server trust requirements; use the case-specific result “Repeat a documented regression test confirming: login requests reach only the authorized AAA server through the permitted management path”.

B:

“Repeat a documented regression test confirming: the correct image is validated and accepted for the intended node upgrade group” is a regression check for the selected firmware image is not compatible with the targeted ACI nodes. It does not retest the actual failure, the AAA integration does not meet the deployment's approved management transport and server trust requirements; use the case-specific result “Repeat a documented regression test confirming: login requests reach only the authorized AAA server through the permitted management path”.

C:

“Repeat a documented regression test confirming: only authorized recovery personnel can retrieve configuration exports and access is logged” is a regression check for backup custody lacks the access control and protection required for sensitive configuration material. It does not retest the actual failure, the AAA integration does not meet the deployment's approved management transport and server trust requirements; use the case-specific result “Repeat a documented regression test confirming: login requests reach only the authorized AAA server through the permitted management path”.

Question 675

At fictional Trellis Education, the team is reviewing shortcuts for the following ACI issue: An administrator configures authentication against a remote server over an unapproved unsecured management path. Which proposal would recreate the same failure?

  1. Expose the AAA server to the public internet solely to avoid internal routing.
  2. Upgrade every leaf independently to an arbitrary version before validating the controller release.
  3. Force a package built for a different hardware family onto the target leaf.
  4. Publish configuration snapshots in a general employee document folder to simplify rollback.

Explanation

Correct Answer

A:

This proposal reintroduces the underlying failure: The AAA integration does not meet the deployment's approved management transport and server trust requirements. The supported alternative is: Configure a supported authenticated AAA path over the approved management network and verify server trust.

Incorrect Answers

B:

“Upgrade every leaf independently to an arbitrary version before validating the controller release” represents a different ACI defect involving the maintenance plan does not follow supported controller/switch version compatibility and ordering. The shortcut sought here preserves the AAA integration does not meet the deployment's approved management transport and server trust requirements, so the relevant answer is “Expose the AAA server to the public internet solely to avoid internal routing”.

C:

“Force a package built for a different hardware family onto the target leaf” represents a different ACI defect involving the selected firmware image is not compatible with the targeted ACI nodes. The shortcut sought here preserves the AAA integration does not meet the deployment's approved management transport and server trust requirements, so the relevant answer is “Expose the AAA server to the public internet solely to avoid internal routing”.

D:

“Publish configuration snapshots in a general employee document folder to simplify rollback” represents a different ACI defect involving backup custody lacks the access control and protection required for sensitive configuration material. The shortcut sought here preserves the AAA integration does not meet the deployment's approved management transport and server trust requirements, so the relevant answer is “Expose the AAA server to the public internet solely to avoid internal routing”.

Question 676

A Cisco ACI deployment review at fictional Alder Financial identifies this condition: An engineer starts a leaf firmware upgrade before confirming the compatible APIC release and upgrade sequence. What is the most appropriate next configuration action?

  1. Resolve or risk-accept documented blockers and rerun supported pre-upgrade checks.
  2. Run approved post-upgrade fabric checks and representative tenant and external path tests.
  3. Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence.
  4. Correct the APIC out-of-band management addressing and external management reachability.

Explanation

Correct Answer

C:

The direct correction is to validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence. This addresses the specific defect: The maintenance plan does not follow supported controller/switch version compatibility and ordering. Validate the outcome by confirming: The controller and selected leaf versions satisfy the published compatibility requirements after upgrade.

Incorrect Answers

A:

“Resolve or risk-accept documented blockers and rerun supported pre-upgrade checks” addresses the upgrade process has ignored readiness faults that could compromise maintenance reliability, but the ACI fault here is the maintenance plan does not follow supported controller/switch version compatibility and ordering. The appropriate implementation is “Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence”.

B:

“Run approved post-upgrade fabric checks and representative tenant and external path tests” addresses upgrade completion state is being used without application forwarding and health validation, but the ACI fault here is the maintenance plan does not follow supported controller/switch version compatibility and ordering. The appropriate implementation is “Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence”.

D:

“Correct the APIC out-of-band management addressing and external management reachability” addresses the OOB management interface, gateway or external OOB routing is not configured for the approved network, but the ACI fault here is the maintenance plan does not follow supported controller/switch version compatibility and ordering. The appropriate implementation is “Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence”.

Question 677

At fictional Alder Financial, an ACI deployment failed in this way: An engineer starts a leaf firmware upgrade before confirming the compatible APIC release and upgrade sequence. Which technical cause best explains it?

  1. The upgrade process has ignored readiness faults that could compromise maintenance reliability.
  2. The maintenance plan does not follow supported controller/switch version compatibility and ordering.
  3. Upgrade completion state is being used without application forwarding and health validation.
  4. The OOB management interface, gateway or external OOB routing is not configured for the approved network.

Explanation

Correct Answer

B:

The configuration explains the observed behavior because the maintenance plan does not follow supported controller/switch version compatibility and ordering. The remedy is: Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence.

Incorrect Answers

A:

“The upgrade process has ignored readiness faults that could compromise maintenance reliability” would imply the upgrade process has ignored readiness faults that could compromise maintenance reliability. The observed fabric issue instead points to the maintenance plan does not follow supported controller/switch version compatibility and ordering.

C:

“Upgrade completion state is being used without application forwarding and health validation” would imply upgrade completion state is being used without application forwarding and health validation. The observed fabric issue instead points to the maintenance plan does not follow supported controller/switch version compatibility and ordering.

D:

“The OOB management interface, gateway or external OOB routing is not configured for the approved network” would imply the OOB management interface, gateway or external OOB routing is not configured for the approved network. The observed fabric issue instead points to the maintenance plan does not follow supported controller/switch version compatibility and ordering.

Question 678

For the ACI issue at fictional Alder Financial: An engineer starts a leaf firmware upgrade before confirming the compatible APIC release and upgrade sequence. Which finding best demonstrates a successful implementation?

  1. The fabric passes the approved pre-upgrade health gate before installation begins.
  2. Node health, routing adjacencies, EPG reachability and selected service transactions meet the change baseline.
  3. Administrators can reach APIC through the dedicated OOB path without reliance on tenant endpoints.
  4. The controller and selected leaf versions satisfy the published compatibility requirements after upgrade.

Explanation

Correct Answer

D:

This verifies the intended ACI change: Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence. It addresses the original behavior rather than only showing unrelated system health.

Incorrect Answers

A:

“The fabric passes the approved pre-upgrade health gate before installation begins” could verify the upgrade process has ignored readiness faults that could compromise maintenance reliability, not the maintenance plan does not follow supported controller/switch version compatibility and ordering. Confirm instead that the controller and selected leaf versions satisfy the published compatibility requirements after upgrade.

B:

“Node health, routing adjacencies, EPG reachability and selected service transactions meet the change baseline” could verify upgrade completion state is being used without application forwarding and health validation, not the maintenance plan does not follow supported controller/switch version compatibility and ordering. Confirm instead that the controller and selected leaf versions satisfy the published compatibility requirements after upgrade.

C:

“Administrators can reach APIC through the dedicated OOB path without reliance on tenant endpoints” could verify the OOB management interface, gateway or external OOB routing is not configured for the approved network, not the maintenance plan does not follow supported controller/switch version compatibility and ordering. Confirm instead that the controller and selected leaf versions satisfy the published compatibility requirements after upgrade.

Question 679

Following remediation at fictional Alder Financial, what recurring validation should guard against this failure returning? The original issue was: An engineer starts a leaf firmware upgrade before confirming the compatible APIC release and upgrade sequence.

  1. Repeat a documented regression test confirming: the fabric passes the approved pre-upgrade health gate before installation begins.
  2. Repeat a documented regression test confirming: node health, routing adjacencies, EPG reachability and selected service transactions meet the change baseline.
  3. Repeat a documented regression test confirming: the controller and selected leaf versions satisfy the published compatibility requirements after upgrade.
  4. Repeat a documented regression test confirming: administrators can reach APIC through the dedicated OOB path without reliance on tenant endpoints.

Explanation

Correct Answer

C:

The selected control exercises the intended APIC and leaf upgrade sequencing design. Without checking this result, the team may overlook a recurrence of the original issue.

Incorrect Answers

A:

“Repeat a documented regression test confirming: the fabric passes the approved pre-upgrade health gate before installation begins” is a regression check for the upgrade process has ignored readiness faults that could compromise maintenance reliability. It does not retest the actual failure, the maintenance plan does not follow supported controller/switch version compatibility and ordering; use the case-specific result “Repeat a documented regression test confirming: the controller and selected leaf versions satisfy the published compatibility requirements after upgrade”.

B:

“Repeat a documented regression test confirming: node health, routing adjacencies, EPG reachability and selected service transactions meet the change baseline” is a regression check for upgrade completion state is being used without application forwarding and health validation. It does not retest the actual failure, the maintenance plan does not follow supported controller/switch version compatibility and ordering; use the case-specific result “Repeat a documented regression test confirming: the controller and selected leaf versions satisfy the published compatibility requirements after upgrade”.

D:

“Repeat a documented regression test confirming: administrators can reach APIC through the dedicated OOB path without reliance on tenant endpoints” is a regression check for the OOB management interface, gateway or external OOB routing is not configured for the approved network. It does not retest the actual failure, the maintenance plan does not follow supported controller/switch version compatibility and ordering; use the case-specific result “Repeat a documented regression test confirming: the controller and selected leaf versions satisfy the published compatibility requirements after upgrade”.

Question 680

A change reviewer at fictional Alder Financial sees: An engineer starts a leaf firmware upgrade before confirming the compatible APIC release and upgrade sequence. Which tempting simplification should be rejected?

  1. Upgrade every leaf independently to an arbitrary version before validating the controller release.
  2. Treat a critical pre-upgrade fault as a cosmetic warning and upgrade all nodes simultaneously.
  3. Close the change solely because all switch firmware versions match.
  4. Rely solely on a tenant bridge domain to replace required OOB APIC management connectivity.

Explanation

Correct Answer

A:

This proposal reintroduces the underlying failure: The maintenance plan does not follow supported controller/switch version compatibility and ordering. The supported alternative is: Validate Cisco release guidance and perform the approved APIC/fabric upgrade sequence.

Incorrect Answers

B:

“Treat a critical pre-upgrade fault as a cosmetic warning and upgrade all nodes simultaneously” represents a different ACI defect involving the upgrade process has ignored readiness faults that could compromise maintenance reliability. The shortcut sought here preserves the maintenance plan does not follow supported controller/switch version compatibility and ordering, so the relevant answer is “Upgrade every leaf independently to an arbitrary version before validating the controller release”.

C:

“Close the change solely because all switch firmware versions match” represents a different ACI defect involving upgrade completion state is being used without application forwarding and health validation. The shortcut sought here preserves the maintenance plan does not follow supported controller/switch version compatibility and ordering, so the relevant answer is “Upgrade every leaf independently to an arbitrary version before validating the controller release”.

D:

“Rely solely on a tenant bridge domain to replace required OOB APIC management connectivity” represents a different ACI defect involving the OOB management interface, gateway or external OOB routing is not configured for the approved network. The shortcut sought here preserves the maintenance plan does not follow supported controller/switch version compatibility and ordering, so the relevant answer is “Upgrade every leaf independently to an arbitrary version before validating the controller release”.

Implementing Cisco Application Centric Infrastructure (DCACI) (300-620) Practice Tests

Purchase Cisco DCACI 300-620 Exam Training Products Individually

300-620 Questions & Answers
Premium File
450 Questions & Answers
Last Update: Nov 15, 2026
$59.99
300-620 Training Course
38 Lectures
$24.99
300-620 Study Guide
Study Guide
1221 Pages
$24.99
accept downloads in the last 7 days
What exactly is 300-620 Premium File?

The 300-620 Premium File has been developed by industry professionals, who have been working with IT certifications for years and have close ties with IT certification vendors and holders - with most recent exam questions and valid answers.

300-620 Premium File is presented in VCE format. VCE (Virtual CertExam) is a file format that realistically simulates 300-620 exam environment, allowing for the most convenient exam preparation you can get - in the convenience of your own home or on the go. If you have ever seen IT exam simulations, chances are, they were in the VCE format.

What is VCE?

VCE is a file format associated with Visual CertExam Software. This format and software are widely used for creating tests for IT certifications. To create and open VCE files, you will need to purchase, download and install VCE Exam Simulator on your computer.

Can I try it for free?

Yes, you can. Look through free VCE files section and download any file you choose absolutely free.

Where do I get VCE Exam Simulator?

VCE Exam Simulator can be purchased from its developer, https://www.avanset.com. Please note that Exam-Labs does not sell or support this software. Should you have any questions or concerns about using this product, please contact Avanset support team directly.

How are Premium VCE files different from Free VCE files?

Premium VCE files have been developed by industry professionals, who have been working with IT certifications for years and have close ties with IT certification vendors and holders - with most recent exam questions and some insider information.

Free VCE files All files are sent by Exam-labs community members. We encourage everyone who has recently taken an exam and/or has come across some braindumps that have turned out to be true to share this information with the community by creating and sending VCE files. We don't say that these free VCEs sent by our members aren't reliable (experience shows that they are). But you should use your critical thinking as to what you download and memorize.

How long will I receive updates for 300-620 Premium VCE File that I purchased?

Free updates are available during 30 days after you purchased Premium VCE file. After 30 days the file will become unavailable.

How can I get the products after purchase?

All products are available for download immediately from your Member's Area. Once you have made the payment, you will be transferred to Member's Area where you can login and download the products you have purchased to your PC or another device.

Will I be able to renew my products when they expire?

Yes, when the 30 days of your product validity are over, you have the option of renewing your expired products with a 30% discount. This can be done in your Member's Area.

Please note that you will not be able to use the product after it has expired if you don't renew it.

How often are the questions updated?

We always try to provide the latest pool of questions, Updates in the questions depend on the changes in actual pool of questions by different vendors. As soon as we know about the change in the exam question pool we try our best to update the products as fast as possible.

What is a Study Guide?

Study Guides available on Exam-Labs are built by industry professionals who have been working with IT certifications for years. Study Guides offer full coverage on exam objectives in a systematic approach. Study Guides are very useful for fresh applicants and provides background knowledge about preparation of exams.

How can I open a Study Guide?

Any study guide can be opened by an official Acrobat by Adobe or any other reader application you use.

What is a Training Course?

Training Courses we offer on Exam-Labs in video format are created and managed by IT professionals. The foundation of each course are its lectures, which can include videos, slides and text. In addition, authors can add resources and various types of practice activities, as a way to enhance the learning experience of students.

Enter Your Email Address to Proceed

Please fill out your email address below in order to purchase Certification/Exam.

A confirmation link will be sent to this email address to verify your login.

Make sure to enter correct email address.

Enter Your Email Address to Proceed

Please fill out your email address below in order to purchase Demo.

A confirmation link will be sent to this email address to verify your login.

Make sure to enter correct email address.

Still Not Convinced?

Download 12 Sample Questions that you Will see in your
Cisco 300-620 exam.

Download 12 Free Questions

or Guarantee your success by buying the full version which covers
the full latest pool of questions. (450 Questions, Last Updated on
Nov 15, 2026)

How It Works

Download Exam
Step 1. Choose Exam
on Exam-Labs
Download IT Exams Questions & Answers
Download Avanset Simulator
Step 2. Open Exam with
Avanset Exam Simulator
Press here to download VCE Exam Simulator that simulates latest exam environment
Study
Step 3. Study
& Pass
IT Exams Anywhere, Anytime!

SPECIAL OFFER: GET 10% OFF. This is ONE TIME OFFER

You save
10%
Save
Exam-Labs Special Discount

Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login

* We value your privacy. We will not rent or sell your email address.

SPECIAL OFFER: GET 10% OFF

You save
10%
Save
Exam-Labs Special Discount

USE DISCOUNT CODE:

A confirmation link was sent to your email.

Please check your mailbox for a message from [email protected] and follow the directions.