Implementing Cisco Application Centric Infrastructure (DCACI) 300-620 Practice Test 74
Question 730
At fictional Trellis Education, the team is reviewing shortcuts for the following ACI issue: A newly commissioned ACI pod cannot exchange overlay reachability with the existing pod although each pod's local fabric is healthy. Which proposal would recreate the same failure?
- Reuse the first pod's ID because the second pod is in another building.
- Maintain conflicting copies of the same tenant policy on nonexistent independent pod controllers.
- Connect the two pod fabrics with an arbitrary tenant access VLAN instead of a validated IPN.
- Treat every site-local object as disposable whenever a global schema is synchronized.
Explanation
Correct Answer
C:This proposal reintroduces the underlying failure: The Inter-Pod Network does not meet the required routed connectivity between the pods' infrastructure endpoints. The supported alternative is: Verify the supported Multi-Pod IPN routing, addressing, MTU and connectivity prerequisites.
Incorrect Answers
A:“Reuse the first pod's ID because the second pod is in another building” represents a different ACI defect involving the Multi-Pod deployment has conflicting fabric pod identities. The shortcut sought here preserves the Inter-Pod Network does not meet the required routed connectivity between the pods' infrastructure endpoints, so the relevant answer is “Connect the two pod fabrics with an arbitrary tenant access VLAN instead of a validated IPN”.
B:“Maintain conflicting copies of the same tenant policy on nonexistent independent pod controllers” represents a different ACI defect involving the operational model misunderstands shared fabric policy and pod-specific infrastructure configuration. The shortcut sought here preserves the Inter-Pod Network does not meet the required routed connectivity between the pods' infrastructure endpoints, so the relevant answer is “Connect the two pod fabrics with an arbitrary tenant access VLAN instead of a validated IPN”.
D:“Treat every site-local object as disposable whenever a global schema is synchronized” represents a different ACI defect involving the design does not distinguish orchestrator-owned global policy from approved local site configuration. The shortcut sought here preserves the Inter-Pod Network does not meet the required routed connectivity between the pods' infrastructure endpoints, so the relevant answer is “Connect the two pod fabrics with an arbitrary tenant access VLAN instead of a validated IPN”.
Question 731
A Cisco ACI deployment review at fictional Alder Financial identifies this condition: A second pod is assigned the same pod ID as the existing production pod during expansion. What is the most appropriate next configuration action?
- Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage.
- Allocate the correct unique pod identifier and validate node-to-pod registration.
- Use the supported ACI Multi-Site model with independently managed sites and coordinated intersite policies.
- Validate local APIC autonomy and documented orchestrator unavailability behavior for each site.
Explanation
Correct Answer
B:The direct correction is to allocate the correct unique pod identifier and validate node-to-pod registration. This addresses the specific defect: The Multi-Pod deployment has conflicting fabric pod identities. Validate the outcome by confirming: All nodes show their intended unique pod membership without identity collisions.
Incorrect Answers
A:“Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage” addresses the availability plan has not separated inter-pod reachability from local pod service continuity, but the ACI fault here is the Multi-Pod deployment has conflicting fabric pod identities. The appropriate implementation is “Allocate the correct unique pod identifier and validate node-to-pod registration”.
C:“Use the supported ACI Multi-Site model with independently managed sites and coordinated intersite policies” addresses the topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster, but the ACI fault here is the Multi-Pod deployment has conflicting fabric pod identities. The appropriate implementation is “Allocate the correct unique pod identifier and validate node-to-pod registration”.
D:“Validate local APIC autonomy and documented orchestrator unavailability behavior for each site” addresses the team confuses independent site-level control planes with a single Multi-Pod APIC cluster, but the ACI fault here is the Multi-Pod deployment has conflicting fabric pod identities. The appropriate implementation is “Allocate the correct unique pod identifier and validate node-to-pod registration”.
Question 732
At fictional Alder Financial, an ACI deployment failed in this way: A second pod is assigned the same pod ID as the existing production pod during expansion. Which technical cause best explains it?
- The availability plan has not separated inter-pod reachability from local pod service continuity.
- The topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster.
- The Multi-Pod deployment has conflicting fabric pod identities.
- The team confuses independent site-level control planes with a single Multi-Pod APIC cluster.
Explanation
Correct Answer
C:The configuration explains the observed behavior because the Multi-Pod deployment has conflicting fabric pod identities. The remedy is: Allocate the correct unique pod identifier and validate node-to-pod registration.
Incorrect Answers
A:“The availability plan has not separated inter-pod reachability from local pod service continuity” would imply the availability plan has not separated inter-pod reachability from local pod service continuity. The observed fabric issue instead points to the Multi-Pod deployment has conflicting fabric pod identities.
B:“The topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster” would imply the topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster. The observed fabric issue instead points to the Multi-Pod deployment has conflicting fabric pod identities.
D:“The team confuses independent site-level control planes with a single Multi-Pod APIC cluster” would imply the team confuses independent site-level control planes with a single Multi-Pod APIC cluster. The observed fabric issue instead points to the Multi-Pod deployment has conflicting fabric pod identities.
Question 733
For the ACI issue at fictional Alder Financial: A second pod is assigned the same pod ID as the existing production pod during expansion. Which finding best demonstrates a successful implementation?
- The supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
- Each site retains its own APIC control plane while shared policies are deployed through the approved orchestrator.
- All nodes show their intended unique pod membership without identity collisions.
- Healthy sites retain appropriate locally managed ACI operation during an isolated peer-site controller outage.
Explanation
Correct Answer
C:This verifies the intended ACI change: Allocate the correct unique pod identifier and validate node-to-pod registration. It addresses the original behavior rather than only showing unrelated system health.
Incorrect Answers
A:“The supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior” could verify the availability plan has not separated inter-pod reachability from local pod service continuity, not the Multi-Pod deployment has conflicting fabric pod identities. Confirm instead that all nodes show their intended unique pod membership without identity collisions.
B:“Each site retains its own APIC control plane while shared policies are deployed through the approved orchestrator” could verify the topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster, not the Multi-Pod deployment has conflicting fabric pod identities. Confirm instead that all nodes show their intended unique pod membership without identity collisions.
D:“Healthy sites retain appropriate locally managed ACI operation during an isolated peer-site controller outage” could verify the team confuses independent site-level control planes with a single Multi-Pod APIC cluster, not the Multi-Pod deployment has conflicting fabric pod identities. Confirm instead that all nodes show their intended unique pod membership without identity collisions.
Question 734
Following remediation at fictional Alder Financial, what recurring validation should guard against this failure returning? The original issue was: A second pod is assigned the same pod ID as the existing production pod during expansion.
- Repeat a documented regression test confirming: the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
- Repeat a documented regression test confirming: each site retains its own APIC control plane while shared policies are deployed through the approved orchestrator.
- Repeat a documented regression test confirming: healthy sites retain appropriate locally managed ACI operation during an isolated peer-site controller outage.
- Repeat a documented regression test confirming: all nodes show their intended unique pod membership without identity collisions.
Explanation
Correct Answer
D:The selected control exercises the intended Multi-Pod pod identifiers design. Without checking this result, the team may overlook a recurrence of the original issue.
Incorrect Answers
A:“Repeat a documented regression test confirming: the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior” is a regression check for the availability plan has not separated inter-pod reachability from local pod service continuity. It does not retest the actual failure, the Multi-Pod deployment has conflicting fabric pod identities; use the case-specific result “Repeat a documented regression test confirming: all nodes show their intended unique pod membership without identity collisions”.
B:“Repeat a documented regression test confirming: each site retains its own APIC control plane while shared policies are deployed through the approved orchestrator” is a regression check for the topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster. It does not retest the actual failure, the Multi-Pod deployment has conflicting fabric pod identities; use the case-specific result “Repeat a documented regression test confirming: all nodes show their intended unique pod membership without identity collisions”.
C:“Repeat a documented regression test confirming: healthy sites retain appropriate locally managed ACI operation during an isolated peer-site controller outage” is a regression check for the team confuses independent site-level control planes with a single Multi-Pod APIC cluster. It does not retest the actual failure, the Multi-Pod deployment has conflicting fabric pod identities; use the case-specific result “Repeat a documented regression test confirming: all nodes show their intended unique pod membership without identity collisions”.
Question 735
A change reviewer at fictional Alder Financial sees: A second pod is assigned the same pod ID as the existing production pod during expansion. Which tempting simplification should be rejected?
- Disable both healthy local fabrics whenever one IPN circuit is lost.
- Merge unrelated APIC clusters merely by assigning identical tenant names.
- Reuse the first pod's ID because the second pod is in another building.
- Power off all site controllers to simulate one fabric's APIC failure without planning impact.
Explanation
Correct Answer
C:This proposal reintroduces the underlying failure: The Multi-Pod deployment has conflicting fabric pod identities. The supported alternative is: Allocate the correct unique pod identifier and validate node-to-pod registration.
Incorrect Answers
A:“Disable both healthy local fabrics whenever one IPN circuit is lost” represents a different ACI defect involving the availability plan has not separated inter-pod reachability from local pod service continuity. The shortcut sought here preserves the Multi-Pod deployment has conflicting fabric pod identities, so the relevant answer is “Reuse the first pod's ID because the second pod is in another building”.
B:“Merge unrelated APIC clusters merely by assigning identical tenant names” represents a different ACI defect involving the topology needs Multi-Site orchestration rather than pretending independent fabrics share one APIC cluster. The shortcut sought here preserves the Multi-Pod deployment has conflicting fabric pod identities, so the relevant answer is “Reuse the first pod's ID because the second pod is in another building”.
D:“Power off all site controllers to simulate one fabric's APIC failure without planning impact” represents a different ACI defect involving the team confuses independent site-level control planes with a single Multi-Pod APIC cluster. The shortcut sought here preserves the Multi-Pod deployment has conflicting fabric pod identities, so the relevant answer is “Reuse the first pod's ID because the second pod is in another building”.
Question 736
Engineers at fictional Bluehaven Systems report: One IPN routed path fails and the operator assumes both pods must shut down even though local connectivity remains healthy. Which implementation step should be prioritized?
- Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage.
- Validate current Cisco Multi-Pod distance, latency, bandwidth and IPN design requirements before rollout.
- Use Nexus Dashboard Orchestrator to govern approved site templates and deploy policy to the intended fabrics.
- Use supported Remote Leaf architecture to attach remote leaves to the parent fabric over the approved transport.
Explanation
Correct Answer
A:Choosing this targeted change is preferable to modifying unrelated policies. Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage. The evidence of success should be: The supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
Incorrect Answers
B:“Validate current Cisco Multi-Pod distance, latency, bandwidth and IPN design requirements before rollout” addresses the geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency, but the ACI fault here is the availability plan has not separated inter-pod reachability from local pod service continuity. The appropriate implementation is “Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage”.
C:“Use Nexus Dashboard Orchestrator to govern approved site templates and deploy policy to the intended fabrics” addresses the intersite governance process lacks a supported shared policy orchestration workflow, but the ACI fault here is the availability plan has not separated inter-pod reachability from local pod service continuity. The appropriate implementation is “Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage”.
D:“Use supported Remote Leaf architecture to attach remote leaves to the parent fabric over the approved transport” addresses the Remote Leaf extension model is being confused with a complete additional ACI pod, but the ACI fault here is the availability plan has not separated inter-pod reachability from local pod service continuity. The appropriate implementation is “Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage”.
Question 737
After checking the symptoms at fictional Bluehaven Systems: One IPN routed path fails and the operator assumes both pods must shut down even though local connectivity remains healthy. Which policy or topology defect is most likely?
- The availability plan has not separated inter-pod reachability from local pod service continuity.
- The geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency.
- The intersite governance process lacks a supported shared policy orchestration workflow.
- The Remote Leaf extension model is being confused with a complete additional ACI pod.
Explanation
Correct Answer
A:The described topology and policy would produce the symptom because the availability plan has not separated inter-pod reachability from local pod service continuity. The planned fix should be: Validate redundant IPN connectivity and document local-pod behavior for an inter-pod outage.
Incorrect Answers
B:“The geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency” would imply the geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency. The observed fabric issue instead points to the availability plan has not separated inter-pod reachability from local pod service continuity.
C:“The intersite governance process lacks a supported shared policy orchestration workflow” would imply the intersite governance process lacks a supported shared policy orchestration workflow. The observed fabric issue instead points to the availability plan has not separated inter-pod reachability from local pod service continuity.
D:“The Remote Leaf extension model is being confused with a complete additional ACI pod” would imply the Remote Leaf extension model is being confused with a complete additional ACI pod. The observed fabric issue instead points to the availability plan has not separated inter-pod reachability from local pod service continuity.
Question 738
After the ACI configuration is corrected at fictional Bluehaven Systems, the engineer needs proof that this issue is resolved: One IPN routed path fails and the operator assumes both pods must shut down even though local connectivity remains healthy. Which observation is the strongest evidence?
- The chosen transport meets documented support limits and representative cross-pod traffic passes.
- Both site fabrics receive consistent orchestrated tenant policy while site-local objects remain independently managed.
- The remote leaf registers under the intended fabric and uses the validated remote connectivity without local spine deployment.
- The supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
Explanation
Correct Answer
D:The outcome directly tests the corrected Multi-Pod IPN failure boundary behavior. The supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior. It provides stronger evidence than a generic green dashboard or link-up check.
Incorrect Answers
A:“The chosen transport meets documented support limits and representative cross-pod traffic passes” could verify the geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency, not the availability plan has not separated inter-pod reachability from local pod service continuity. Confirm instead that the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
B:“Both site fabrics receive consistent orchestrated tenant policy while site-local objects remain independently managed” could verify the intersite governance process lacks a supported shared policy orchestration workflow, not the availability plan has not separated inter-pod reachability from local pod service continuity. Confirm instead that the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
C:“The remote leaf registers under the intended fabric and uses the validated remote connectivity without local spine deployment” could verify the Remote Leaf extension model is being confused with a complete additional ACI pod, not the availability plan has not separated inter-pod reachability from local pod service continuity. Confirm instead that the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
Question 739
A maintenance standard is being revised after this ACI fault at fictional Bluehaven Systems: One IPN routed path fails and the operator assumes both pods must shut down even though local connectivity remains healthy. Which ongoing verification is most relevant?
- Repeat a documented regression test confirming: the chosen transport meets documented support limits and representative cross-pod traffic passes.
- Repeat a documented regression test confirming: both site fabrics receive consistent orchestrated tenant policy while site-local objects remain independently managed.
- Repeat a documented regression test confirming: the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
- Repeat a documented regression test confirming: the remote leaf registers under the intended fabric and uses the validated remote connectivity without local spine deployment.
Explanation
Correct Answer
C:The safeguard focuses on the actual root defect: The availability plan has not separated inter-pod reachability from local pod service continuity. Retesting this outcome can catch a later policy or topology drift.
Incorrect Answers
A:“Repeat a documented regression test confirming: the chosen transport meets documented support limits and representative cross-pod traffic passes” is a regression check for the geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency. It does not retest the actual failure, the availability plan has not separated inter-pod reachability from local pod service continuity; use the case-specific result “Repeat a documented regression test confirming: the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior”.
B:“Repeat a documented regression test confirming: both site fabrics receive consistent orchestrated tenant policy while site-local objects remain independently managed” is a regression check for the intersite governance process lacks a supported shared policy orchestration workflow. It does not retest the actual failure, the availability plan has not separated inter-pod reachability from local pod service continuity; use the case-specific result “Repeat a documented regression test confirming: the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior”.
D:“Repeat a documented regression test confirming: the remote leaf registers under the intended fabric and uses the validated remote connectivity without local spine deployment” is a regression check for the Remote Leaf extension model is being confused with a complete additional ACI pod. It does not retest the actual failure, the availability plan has not separated inter-pod reachability from local pod service continuity; use the case-specific result “Repeat a documented regression test confirming: the supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior”.
Question 740
During a post-incident review at fictional Bluehaven Systems, the original condition was: One IPN routed path fails and the operator assumes both pods must shut down even though local connectivity remains healthy. Which shortcut would leave its cause in place?
- Assume a shared APIC fabric supports unlimited WAN delay and arbitrary packet loss.
- Edit only one site's local APIC and assume the changes automatically propagate to all sites.
- Disable both healthy local fabrics whenever one IPN circuit is lost.
- Install a new spine-and-controller fabric at every Remote Leaf office by definition.
Explanation
Correct Answer
C:Reject it because it defeats the correction for this observed case: One IPN routed path fails and the operator assumes both pods must shut down even though local connectivity remains healthy. The required outcome remains: The supported local workload paths remain healthy and inter-pod traffic follows the documented failover or isolation behavior.
Incorrect Answers
A:“Assume a shared APIC fabric supports unlimited WAN delay and arbitrary packet loss” represents a different ACI defect involving the geographic deployment ignores Multi-Pod transport constraints for control-plane and forwarding consistency. The shortcut sought here preserves the availability plan has not separated inter-pod reachability from local pod service continuity, so the relevant answer is “Disable both healthy local fabrics whenever one IPN circuit is lost”.
B:“Edit only one site's local APIC and assume the changes automatically propagate to all sites” represents a different ACI defect involving the intersite governance process lacks a supported shared policy orchestration workflow. The shortcut sought here preserves the availability plan has not separated inter-pod reachability from local pod service continuity, so the relevant answer is “Disable both healthy local fabrics whenever one IPN circuit is lost”.
D:“Install a new spine-and-controller fabric at every Remote Leaf office by definition” represents a different ACI defect involving the Remote Leaf extension model is being confused with a complete additional ACI pod. The shortcut sought here preserves the availability plan has not separated inter-pod reachability from local pod service continuity, so the relevant answer is “Disable both healthy local fabrics whenever one IPN circuit is lost”.