Limited Time Discount Offer 30% Off - Ends in 02:00:00

×

Network Appliance NS0-506 Exam - NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP

Questions & Answers for Network Appliance NS0-506

Showing 1-15 of 65 Questions

Question #1

Which resource would you use to search for information about the configurations for
NetApp products that work with third-party solutions?

A. Config Advisor

B. Host Utility Kit

C. Interoperability Matrix Tool

D. Clustered Data ONTAP 8.3 SAN Administration Guide

Reference:http://hwu-stage.netapp.com/Resources/FundedTools.htm

Question #2

Hosts and switches are connected to a FAS8040. Multiple FC-enabled SVMs have been
created, and LUNs have been mapped to multiple hosts. During failover testing, one of the
hosts lost connectivity to its LUNs.
What needs to be examined?

A. FAS8040 ALUA configuration

B. host multipath settings

C. xhost iSCSI timeout values

D. switch NPIV settings

Question #3

Which command enables the FC protocol on clustered Data ONTAP?

A. vserverfpolicy enable –vserver<node_name> –policy –name <policy_name> –sequence– number <seq_num>

B. vserverfcp create –vserver<vserver_name> –status –adain up

C. node run node <node_name>fcadmincongig –e

D. vserveriscsi create–vserver<vserver_name> -target –alias <vserver_name>

Reference:https://library.netapp.com/ecmdocs/ECMP1196817/html/vserver/fcp/create.html

Question #4

You have a large, heterogeneousSAN environment. You are asked to gather information
for all hosts, HBAs, switches, and storage. You are also told that you must collect this
information over network protocols without agents.
Which two NetApp tools allow you to perform this task? (Choose two.)

A. OnCommand Insight

B. OnCommand Report

C. OnCommand Unified Manager

D. nSANity

Question #5

Click the Exhibit button.
Referring to the diagram shown in the exhibit, what will happen if PDU-B fails?

A. Both Node A and Node B will remain online and all disk shelves will remain online.

B. Both Node A and Node B will remain online, but all disk shelves will immediately lose power and become inaccessible.

C. Both Node A and Node B willimmediately lose power and become inaccessible.

D. Node A will immediately lose power and become inaccessible. Node B will remain online.

Question #6

Which three environmental or physical requirements need to be met when designing a SAN
solution? (Choose three.)

A. rack space

B. cooling

C. clustered Data ONTAP version

D. IOPS

E. power

Question #7

Click the Exhibit button.
After mapping the LUN on the cluster, you are not able to see in on the Windows 2012
host.
cl01::>igroup show instance
Vserver Name: svm1
Igroup Name: ig1-win
Protocol: iscsi
OS Type: Windows
Portset Binding Igroup: -
Igroup UUID: 358338ba-cfd6-
11df-a9ab-123478563412
Initiators: iqn.1991-
05.com.microsoft: host1 (not
logged in)
Referring to the exhibit, what is the problem?

A. An administrator is not logged into the host.

B. The iSCSI target has not been added to the host.

C. The OS type should be windows_2008.

D. The OS type should be windows_gpt.

Question #8

You are zoning a fabric for a clustered Data ONTAP storage system. After cabling, you see
the following addresses logged into the fabric:
20:04:00:a0:98:16:db:9c
50:0a:09:83:8d:b1:ce:c3
What should be included in the zone configuration?

A. 50:0a:09:83:8d:b1:ce:c3 and the initiator WWNN

B. 50:0a:09:83:8d:b1:ce:c3 and the initiator WWPN

C. 20:04:00:a0:98:16:db:9c and the initiator WWPN

D. 20:04:00:a0:98:16:db:9c and the initiator WWNN

Question #9

A company has 50 ESXi hosts connected using FC to a single target port on a NetApp
cluster. Ten hosts are configured with an HBA queue depth on 128. Forty hosts are
configuredwith a HBA queue depth of 32. They are experiencing performance problems
with their FC LUNs.
Which two actions will resolve the problem? (Choose two.)

A. Use VSC to set recommended values for the hosts.

B. Reduce the HBA queue depth on the on the applicable HBAs.

C. Add additional target ports to allow for greater initiator distribution.

D. Increase the total queue depth on the NetApp cluster.

Question #10

Click the Exhibit button.
cl01::>lun resize vserver
svm1 volume db1_vol lun db1
-size 4096g
Error: command failed: New
size exceeds this LUNs
initial geometry
cl01::>
What is the reason for the error shown in the exhibit?

A. The LUN is thin provisioned, but the parent volume is thick provisioned and cannot satisfy the request.

B. The aggregate over commitment threshold has been exceeded.

C. The parent volume that contains the LUN is out of space.

D. The LUN cannot be grown past its maximum resize size.

Reference:http://community.netapp.com/t5/VMware-Solutions-Discussions/lun-resize/td-
p/8608

Question #11

You have a 4-node FAS8040 cluster licensed for FCP and iSCSI. Each node has both FC
and iSCSI LIFs. One of your Windows 2012 Servers has a single 8Gb FC port and a single
10 Gb Ethernet port with switched connectivity to the FC and Ethernet ports on the cluster.
You need to use both ports on the host for multipath access to a LUN on the NetApp
cluster.
What will accomplish this task?

A. NetApp Data ONTAP DSM for Windows MPIO

B. FCoE HBA

C. iSCSI HBA

D. native Windows MPIO

Question #12

Click the Exhibit button.
cl01::> net int show vserver
svm1
(network interface show)
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
----------- --------- ------
---- ------------------ -----
------- ------ ----
svm1
fc_lif1 up/up
20:0b:00:a0:98:4e:ba:14
cl01-01 3a true
fc_lif2 up/up
20:0c:00:a0:98:4e:ba:14
cl01-023a true
lif1 up/up 172.16.21.31/24
cl01-01 a0a true
lif2 up/up 172.16.21.32/24
cl01-02 a0a true
4 entries were displayed.
cl01::>
Referring to the exhibit, a customer needs to move LIF fc_lif1 to a new port.
Which three actions must be performed to accomplish this task? (Choose three.)

A. Remove LIF from the existing portset.

B. Quiesce all hosts accessing LUNs over the LIF.

C. Take the LIF offline.

D. Update the switch zone to include the new WWPN.

E. Move the LIF to a new home port using thenetwork interface modifycommand.

Question #13

When designing a new SAN solution, which three components should be verified with the
IMT? (Choose three.)

A. the connection protocol

B. the patch panel make and model

C. host OS type and version

D. the type of Ethernet switch

E. the clustered Data ONTAP version

Question #14

What does Selective LUN Mapping (SLM) do?

A. It automates igroup creation.

B. It allows the node and its HA partner to create zones on the SAN fabric to automate LUN mapping.

C. It makes a LUN accessible only through paths on the node owning the LUN and its HA partner.

D. It allows the administrator to automatically create LUNs using SnapDrive for Windows and SnapDrive for UNIX.

Explanation:
Selective LUN Map (SLM) reduces the number of paths from the host to the LUN. With
SLM, when a new LUN map is created, the LUN is accessible only through paths on the
node owning the LUN and its HA partner.
SLM enables management of a single igroup per host and also supports nondisruptive LUN
move operations that do not require portset manipulation or LUN remapping.
Portsets can be used with SLM just as in previous versions of Data ONTAP to further
restrict access of certain targets to certain initiators . When using SLM with portsets, LUNs
will be accessible on the set of LIFs in the portset on the node that owns the LUN and on
that node's HA partner.
Reference:https://library.netapp.com/ecmdocs/ECMP1636035/html/GUID-62ABF745-6017-
40B0-9D65-CE9F7FF66AB3.html

Question #15

You want to verify that a host will be able to see the storage. A LUN is mapped to an igroup
for thehost, and both the host and storage are connected to FC switches.
Which command will provide the path status information from the switch?

A. configure

B. cfgshow

C. fcping

D. zoneshow

You Need Avanset VCE Player in Order to Open VCE Files

AUTUMN SALE: 30% DISCOUNT
This is ONE TIME OFFER

You save
30%

Enter Your Email Address to Receive Your 30% Discount Code

AUTUMN SALE: 30% DISCOUNT

You save
30%

Use Discount Code:

A confirmation link was sent to your e-mail.

Please check your mailbox for a message from support@exam-labs.com and follow the directions.